Current Scenario:
• Wired Temperature Monitoring systems require wires to be run between where the temperature is measured and where the temperature data is stored.
•WIRED TEMPERATURE MONITORING SYSTEMS ARE GENERALLY MUCH MORE EXPENSIVE TO INSTALL DUE TO THE LABOR INVOLVED.
•THERMOMETERS CAN BE ELECTRONIC THESE DAYS, BUT THE FUNCTIONALITY IS THE SAME.
•THE PROBLEM WITH THERMOMETERS IS THAT YOU HAVE TO PHYSICALLY GO AND LOOK AT THE THERMOMETER TO KNOW THE TEMPERATURE, AND THE ONLY WAY TO HAVE RECORDS IS TO MANUALLY RECORD THEM. THIS IS A LABORIOUS PROCESS AND GETS EXPENSIVE.
•
IF YOU HAVE MANY TEMPERATURE-SENSITIVE AREAS THAT YOU WANT TO KEEP AN EYE ON.
•MANUAL DATA ACQUISITION.
• WIRED TEMPERATURE SENSOR ARE ANALOG AND NO MORE ACCURACY.
Our Solution:
The wireless temperature monitoring system wireless transmits temperature readings from the sensors which are placed on your Data Center Rack to the BMS room which can be remotely connected to PC. Temperature readings are then displayed on PC via our user friendly software.
APPLICATIONS CONSIDERATIONS
DATA STORAGE
REQUIREMENTS
PERIODICALLY DATA STORAGE IN DATA BASE
HISTORY OF RACK TEMPERATURE WITH RTC
MONITORING
REQUIREMENTS
TEMPERATURE MONITORING, HUMIDITY MONITORING
INTRODUCTION OF SYSTEM
IDEAL SOLUTION FOR INTERNET DATA CENTERS (IDC)
WHY GO FOR THIS SYSTEM?
COST EFFECTIVE SOLUTION
UP TO 20% ELECTRICITY SAVE
AVOIDING LONG WIRE OR CONDUIT RUNS
LOW COST PER ACCESS POINT
ADDED VALUE
INCREASED OPERATIONAL SAFETY BY CONTINUOUS MONITORING AND BY ALARMING
UNIFORM TO CONTROL TEMPERATURE AND HUMIDITY
ASSURED TEMPERATURE AND HUMIDITY
PROMPT FOR ALARM DECLARATION
ASSIST TO CONTROL AIR FLOW DAMPERI
MOBILE AND FLEXIBLE MONITORING
EASY TO UPGRADE AS YOU GROW
NO INTERNET CONNECTION IS REQUIRED
EASY TO INSTAL
KEY PRODUCT FEATURES-
WIRELESS, PORTABLE, INBUILT POWERED SENSORS.
LIVE AND CONTINUOUS MONITORING.
EACH SENSOR TRANSMITS DATA BY EVERY 3MINUTES, 24/7
RELIABLE AND SECURE DATA.
DATA STORAGE AND TRANSMISSION WITH REAL TIME CLOCK
SOFTWARE PROVIDES REAL-TIME DATA AND LOG FILES.
REPORT GENERATION FUNCTIONALITY.
A SYSTEM THAT IS EFFICIENT TO INSTALL AND EASY TO EXPAND OR MOVE.
NO NEED FOR INTERNET CONNECTION.
USER FRIENDLY.
REDUCES RISK OF HUMAN ERROR.
OUR PRESTIGIOUS INSTALLATIONS……..
TATA COMMUNICATION LTD.
INCOME TAX OF INDIA
NVIDIA
IVY COMPTECH
KOTAK MAHINDRA LTD.
HCL
CANARA BANK
SBI CAPITAL
UNION BANK OF INDIA (UBI)
SOUTH INDIA BANK (SIB)
RELIANCE
BANK OF BARODA
WIPRO PUNJAB
ANDHRA BANK
HARDWARE DEVICES-
Temperature sensor
SEMICONDUCTOR TYPE TEMPERATURE SENSORS
INCLUDES 3 TEMPERATURE SENSOR
SELF-CALIBRATED, RECALIBRATION IS NOT REQUIRED
CONNECTED TO TRANSMITTER UNIT
IS PRECISELY ACCURATE.
RESPOND INSTANTLY
Humidity sensor
SEMICONDUCTOR TYPE HUMIDITY SENSOR
CONNECTED TO TRANSMITTER UNIT.
IT IS FULLY CALIBRATED AND PROVIDES DIGITAL OUTPUT.
LOW POWER CONSUMPTION.
EXCELLENT LONG TERM STABILITY.
Transmitter (slave) Unit
IT MEASURES TEMPERATURE AT 3 DIFFERENT POINTS AT SINGLE RACK USING HIGH PRECISION SEMICONDUCTOR SENSORS.
TRANSMITS DATA THROUGH HIGH FREQUENCY CHANNEL.
SENSE 3 TEMPERATURES: LOWER, MIDDLE AND UPPER.
MOUNTED ON DATA CENTER RACKS.
SELF-POWERED, NO EXTERNAL POWER SUPPLY REQUIRED.
LONG LIFE SPAN UP TO 5 YEARS.
Extender Unit
IT IS A INTERMEDIATE TRANS-RECEIVER.
IT RECEIVES THE DATA FROM TRANSMITTER UNIT AND AMPLIFIES THE DATA
AND TRANSMITS IT TO THE CENTRALIZED MASTER UNIT.
UP TO 16 NO. SLAVE DEVICES CAN BE HANDLED BY ONE EXTENDER UNIT.
OPERATES ON 230V AC SUPPLY.
Master Unit
IT COLLECTS DATA FROM ALL SENSORS.
CONVERTS IT TO RS232 FOR FURTHER INTERPRETATION.
UP TO16 EXTENDER DEVICES CAN BE CONNECTED TO ONE MASTER DEVICE.
EQUIVALENT TO 256 TEMPERATURE SENSORS.
Data Collector PC(Server)
COLLECTS DATA FROM MASTER UNIT USING COM/ USB PORTS.
THE DATA IS STORED IN THE HARD DISC DRIVE FOR FUTURE USAGE.
THE PC FOR INSTALLATION IN BMS ROOM.
SOFTWARE APPLICATIONS-
Live Data
Export Data Tools
Database management
Hall layout representation
Graphical analyses
Live Data
This software application is useful for displaying all live data.
BY USING MODBUS CONNECTIVITY YOU CAN ACCESS LIVE DATA OF EACH SENSOR.
AUTOMATICALLY UPDATED SENSOR DATA.
USER DEFINABLE ALERT LEVELS OR TEMPERATURE STANDARDS
Export Data Tools
THIS APPLICATION IS USEFUL FOR EXPORTING TEMP. DATA AND HUMIDITY DATA WITH DESIRED DATE’S
THE EXPORTED DATA IS IN EXCEL FORMAT.
AT TIME 1 MONTH DATA YOU CAN EXPORT.
EXPORTED DATA WILL BE AVAILABLE IN PARTICULAR ASSIGNED FOLDER.
THE TEMPERATURE SENSOR REPORT AND HUMIDITY SENSOR REPORT ARE IN SEPARATE FOLDER.
Database management
THIS APPLICATION IS USEFUL FOR STORAGE ALL RECEIVED IN ANY BACKEND DATABASE LIKE MYSQL, MSSQL , ORACLE OR ANY TYPE OF DATABASE.
THIS DATABASE UPDATE ON REAL TIME CLOCK.
DATA WILL STORE IN DATABASE WITH SEQUENCE OF RECEIVED PACKETS.
ALL THE DATA STORED IN HARD DISK.
Hall layout representation
THIS APPLICATION IS USEFUL FOR PRESENTING ROOM LAYOUT.
BY MOVING MOUSE POINTER ON PARTICULAR RACK IT WILL SHOW COMBINE LIVE TEMPERATURES.
RACK COLORS CHANGE IF SET LIMITS OUT OF RANGE. E.G. IF TEMP. ABOVE SET LIMIT THEN RACK GETS RED, IF TEMP. WITHIN LIMIT THEN – BLUE COLOR & BELOW LIMIT –GREEN
SET LIMITS ARE SITE SETTABLE.
AUTOMATICALLY UPDATE LIVE PACKET.
5. Graphical analyses
Real time Graphical analysis is available for easy interpretation.
Benefits of wireless temperature system-
RF BASED SYSTEM.
ALERTS OF ON E-MAIL OR SMS ALERTS POSSIBLE
LOW POWER CONSUMPTION AND HIGH TRANSMISSION RANGE.
CONVENIENT MASTER UNIT AND EXTENDER UNIT HAS BEEN DESIGNED TO MOUNT ON A CEILING OR CAGE WALL AND SLAVE UNIT BE PORTABLE TO INSTALL ON RACK.
MONITORING: EASY, REAL TIME AND ACCESSIBLE.
REDUCE ELECTRICITY ENERGY COST.
REDUCE TIME TAKING MANUAL READINGS.
INEXPENSIVE WIRELESS TEMPERATURE SENSOR THAT ALLOW YOU TO MEASURE LOT OF POINTS.
INSTALLATION COSTS ARE LOWER BECAUSE WIRES DO NOT NEED TO BE RUN TO ALL THE AREAS WHERE TEMPERATURE IS MONITORED.
WIRELESS SYSTEMS ARE MUCH MORE MOBILE.
CONCLUSION
SIGNIFICANT TIME SAVE DURING THE INSTALLATION AND NO SIGNAL WIRE NEEDED TO BE ROUTED FROM SENSOR TRANSMITTER TO DATA COLLECTOR POINT.
AS THIS BRIEF SURVEY OF WIRELESS TRANSMITTERS AND RECEIVERS FOR TEMPERATURE MEASUREMENT SHOWS, MANY OF THE OLD LIMITATIONS AND COMPLEXITIES OF POINT-TO-POINT, WIRED INTERCONNECTED SYSTEMS NO LONGER APPLY.
THE ENGINEER, TECHNICIAN CAN USE THESE NEW DEVICES TO GAIN FLEXIBILITY IN MONITORING.
DATA CAN BE COLLECTED AND ANALYZED IN REAL TIME AND FOR LATER USING READILY AVAILABLE.